The Safest Lithium Chemistry Available
The Yinlong 45Ah LTO offers 20,000+ cycles and operates from -40°C to +55°C.
Key Features
- 20,000+ cycle life
- No thermal runaway risk
- Wide temp: -40°C to +55°C
Technical Specifications
| Specification | Value |
|---|---|
| Manufacturer | Yinlong |
| Chemistry | LTO |
| Capacity | 45Ah |
| Nominal Voltage | 2.3V |
| Max Voltage | 2.8V |
| Cycle Life | 20,000+ |
| Operating Temp | -40°C ~ +55°C |
| Format | Prismatic |
Safety Warning for Lithium Battery Usage
Customers should have a clear understanding of lithium battery handling and safety before making a purchase. Lithium batteries are highly sensitive and may pose fire, burn, or explosion risks if improperly handled. Always charge batteries on fire-resistant surfaces, and never leave them charging unattended.
- Not for Use in E-Cigarettes or Similar Devices
- Risk of Fire and Explosion: Misuse can cause batteries to ignite, explode, or release harmful gases.
- Always Use in a Protected Pack with appropriate BMS circuitry.
- Proper Storage and Handling: Store in protective cases, away from metal items.
- Inspection Prior to Use: Do not use batteries with damaged wrappers or visible damage.
- Follow Manufacturer Charging Specs: Avoid overcharging or over-discharging.
- Heat and Water Precautions: Do not expose to high temperatures or liquids.
- Assembly: Batteries should only be spot welded; do not solder directly onto terminals.
For Resellers: Please ensure all safety information is passed along to end users.
Cell Specification
| Item | Specification and comments |
|---|---|
| Rated Capacity | 45Ah – initial capacity at 25±5°C, 1I1 (45A) standard charge and 1I1 (45A) standard discharge to cut-off voltage |
| Nominal Voltage | 2.3V |
| Internal Impedance | ≈1.0mΩ – measured by AC 1kHz at 50% SOC |
| Standard Charge Cut-off Voltage | 2.8V |
| Standard Discharge Cut-off Voltage | 1.5V |
| Maximum Continuous Charge Current | 6I1 (270A) at 25±5°C |
| Maximum Continuous Discharge Current | 6I1 (270A) at 25±5°C |
| Maximum Pulse Charge/Discharge Current (10s) | 10I1 (450A) at 25±5°C |
| Operating Temperature Range | Temperature: -40~65°C; Humidity: ≈85%RH. Recommended charge/discharge current ≈1I1 (45A) when cell temperature <0°C; recommended cooling when cell temperature >35°C. |
| Storage Temperature Range | -5~28°C (recommended 25±3°C); storage humidity ≈90%RH |
| Dimension | Diameter: 66.0±1.0mm; Height: 161.0±1.0mm (see scheme of the cell structure) |
| Weight | 1255.0±20g |