Great power INR21700-6500 12.5A
Great power INR21700-6500D 12.5 A discharge.
Technical Specifications
| Model | Great power INR21700-6500 12.5A |
| Format | 21700 |
| Nominal Capacity | |
| Discharge Current | 12.5A |
| Brand | Great Power |
Safety Warning
Unprotected cell. Always use with a BMS. Never short-circuit or overcharge. Keep away from fire and extreme heat. Not for use in e-cigarettes or similar devices.
Cell Specification
| Item | Specification and comments |
|---|---|
| Rated Capacity | 6500mAh – Charge: CC 1250mA / CV 4.2V, 125mA cut-off; Discharge: CC 1250mA to 2.5V |
| Nominal Voltage | 3.5V |
| Delivery Voltage | 3.30–3.50V (within 10 days from factory) |
| Limited Charge Voltage | 4.20V |
| Upper Limited Charge Voltage | 4.20V |
| Standard Charge | CC 1250mA / CV 4.2V, 125mA cut-off |
| End of Discharge Voltage | 2.5V |
| Discharge Cut-off Voltage | 2.5V |
| Standard Discharge | CC 1250mA, 2.5V cut-off |
| ACIR | ≈25mΩ (PTC-free), measured at 1kHz AC at 30% SOC |
| Weight of Cell | ≈74g |
| Recommended Charge Current | 3000mA – CC-CV charge mode |
| Maximum Charge Current | 4500mA |
| Recommended Discharge Current | 7500mA – constant current discharge |
| Maximum Discharge Current | 12500mA |
| Charge and Discharge Condition at Different Temperature | See table: Charge 0–5°C 650mA; 5–15°C 3000mA; 15–45°C 4500mA. Discharge 45–65°C 3125mA; 35–45°C 6250mA; 0–35°C 12500mA; -20–0°C 3125mA. Charge below -5°C is prohibited; low temp reduces efficiency and extreme temp shortens cycle life. |
| Storage Temperature and Time | At 25–50% SOC, 60±25% RH: -20–25°C to 12 months; 25–45°C to 3 months; 45–65°C to 1 month, with recharge to 25–50% SOC after storage. |