LINKDATA INR21700S-50P 5000mAh 21700 Li-ion Cell | 50A Continuous

$6.65

The LINKDATA INR21700S-50P is a 3.6 V cylindrical 21700 lithium-ion cell with a minimum standard discharge capacity of 5,000 mAh. LINKDATA specifies 50 A continuous discharge and separately lists 80 A with an 80°C cell-surface cutoff.

In stock

SKU: LINKDATA-INR21700S-50P Category: Tags: , , , Brand:

LINKDATA INR21700S-50P 21700 Lithium-ion Cell

One cell supplies at least 5,000 mAh and 18.0 Wh in the manufacturer’s standard 1 A discharge test to 2.50 V at 25 ± 2°C.

Technical Specifications

Specification Value
Model INR21700S-50P
Manufacturer Linkdata New Energy Co., Ltd.
Format 21700 cylindrical rechargeable lithium-ion cell
Minimum standard discharge capacity 5,000 mAh at 1 A to 2.50 V and 25 ± 2°C
Typical capacity N/A
Nominal voltage 3.6 V
Minimum standard discharge energy 18.0 Wh at 1 A to 2.50 V and 25 ± 2°C
Continuous discharge 50 A without the 80°C cutoff, or 80 A with an 80°C cell-surface cutoff (§3.11).
Bare-cell weight 67.0 ± 1.5 g
Cell dimensions with sleeve 21.35 ± 0.15 mm diameter × 70.7 ± 0.2 mm height, including the grey sleeve.

Pack-design limits. The 80 A figure in §3.11 applies to a cell with an 80°C cutoff. For pack design, §10.1 specifies a 50 A limit per cell in English and below 50 A in Chinese. Section 13 gives the Chinese text precedence. Section 10.2 specifies overcurrent shutdown above approximately 60 A per cell.

Safety Warning

Use a compatible charger and a pack with overcharge, overdischarge and overcurrent protection. Follow the charging limits in the safety instructions. Keep the terminals insulated and avoid using cells with a damaged sleeve.

Cell Specification

Specification Value
Cell model INR21700S-50P
Standard discharge capacity ≥5,000 mAh after standard charge and a 30-minute rest, discharged at 1 A to 2.50 V at 25 ± 2°C (§§3.1, 6.1.1).
Rated discharge capacity (10C) 96% of standard discharge capacity at 50 A (10C) to 2.50 V at 25 ± 2°C (§6.1.4).
Nominal voltage 3.6 V
Standard charge 5 A constant current to 4.20 V, then constant voltage until current falls to 100 mA at 25 ± 2°C (§5.2).
Rated charge 15 A maximum. The fast-charge test uses 15 A to 4.20 V, followed by constant voltage to 100 mA at 25 ± 2°C (§§3.10, 6.1.3).
Charging time ≤2 hours for standard charge (§3.7). The separate charger-design timer at 5 A is listed as 1.5 hours in English and 4 hours in Chinese (§10.1). Section 13 gives the Chinese text precedence.
Standard discharge 1 A (0.2C) to 2.50 V at 25 ± 2°C (§5.3).
Max. continuous discharge current 50 A without the 80°C cutoff, or 80 A with an 80°C cell-surface cutoff (§3.11). See the pack-design limits above.
Max. pulse discharge current 200 A for 10 seconds at 25 ± 2°C (§3.9).
Charge cut-off voltage 4.20 V, with 100 mA termination during the standard constant-voltage phase (§§3.4, 5.2).
Discharge cut-off voltage 2.50 V standard discharge endpoint (§§3.5, 5.3).
Cycle life (high-rate, 30A) ≥60% of initial capacity after 600 cycles with 8 A charging, or after 200 cycles with 15 A charging. Both tests discharge at 30 A to 2.50 V at 25 ± 2°C (§§6.1.8, 6.1.10).
Cycle life (high-rate, 40A) ≥60% of initial capacity after 500 cycles with 8 A charging and 40 A discharge to 2.50 V at 25 ± 2°C (§6.1.9).
Retention characteristics ≥90% capacity recovery after recharge following 30 days of fully charged storage at 60 ± 2°C (§6.1.12).
Initial impedance Cell internal resistance ≤4.0 mΩ (§3.14). DC internal resistance ≤11 mΩ at 50% state of charge with a 5 A, 10-second discharge pulse (§6.1.2).
Operating cell surface temperature Section 3.16 lists −10 to +60°C for charging and −40 to +80°C for discharge. It recommends resuming charge below 45°C after a thermal cutoff and requires discharge to resume below 60°C. Section 9.3 restricts charging to 0–60°C. The separate ambient ranges in §3.16 are −10 to +45°C for charge and −40 to +60°C for discharge.
Storage conditions At 20–30% state of charge, −20 to +60°C for 1 month, −20 to +45°C for 3 months, or −20 to +25°C for 1 year (§3.15). For long-term storage, §8.2 recommends 0–20°C and relative humidity below 70%.
Shipment voltage 3.580–3.600 V at factory shipment (§6.1.13).
Cell weight 67.0 ± 1.5 g
Cell dimensions (with sleeve) 21.35 ± 0.15 mm diameter × 70.7 ± 0.2 mm height, including the grey sleeve.

Download Manufacturer Data Sheet

Download Manufacturer Data Sheet (PDF)

Battery Safety

Battery Safety & Product Disclaimer

Read before purchasing or using any rechargeable lithium-ion battery.

Rechargeable lithium-ion batteries are high-energy devices that require proper handling and technical knowledge. Improper use can lead to fire, explosion, thermal runaway, serious injury, property damage, or death.

By purchasing products from CH-AmpX, you acknowledge these risks and agree to use all battery products responsibly and in accordance with manufacturer specifications.

Read the Complete Battery Safety Guide

Is This Product Right for You?

CH-AmpX battery cells are intended for:

  • Professional battery pack builders
  • Engineers and product developers
  • Industrial applications
  • Qualified hobbyists familiar with lithium-ion battery technology

These cells are designed to be integrated into battery packs protected by an appropriate Battery Management System (BMS) or Protection Circuit Board (PCB).

They are not intended for standalone consumer use, vaping devices, e-cigarettes, or any application lacking proper battery protection.

Before Every Use

Always inspect every battery before charging, installing, or transporting it.

Do not use any battery that shows signs of:

  • Damaged or torn PVC wrapping
  • Missing insulator ring
  • Dents or crushed casing
  • Swelling or bulging
  • Leakage
  • Corrosion
  • Burn marks or overheating

Using a damaged cell significantly increases the risk of battery failure.

Safe Charging Practices

Battery safety begins with proper charging.

Always:

  • Use a charger designed for lithium-ion batteries.
  • Confirm the charger matches the battery's voltage specifications.
  • Charge on a non-flammable surface.
  • Monitor batteries while charging.

Never:

  • Overcharge or over-discharge a battery.
  • Leave batteries charging unattended.
  • Charge damaged cells.
  • Use incompatible charging equipment.

Safe Storage & Transportation

Improper storage is one of the leading causes of accidental battery incidents.

Never carry loose batteries in:

  • Pockets
  • Backpacks
  • Purses
  • Toolboxes
  • Bags containing metal objects

Contact with keys, coins, tools, or other conductive materials can create a short circuit capable of causing severe burns, fire, or explosion.

Always transport batteries inside protective, non-conductive battery cases.

Store batteries in a cool, dry environment away from excessive heat, moisture, and direct sunlight.

Understanding Thermal Runaway

Thermal runaway is a rapid chain reaction that causes a battery to generate excessive heat, potentially resulting in venting, fire, or explosion.

It may be caused by:

  • Overcharging
  • Short circuits
  • Physical damage
  • Excessive temperatures
  • Internal battery failure

Reducing these risks begins with proper charging, careful handling, and correct battery storage.


Never Do the Following

To reduce the risk of injury or property damage, never:

  • Short circuit a battery.
  • Crush, puncture, or modify the cell.
  • Expose batteries to fire, water, or excessive heat.
  • Charge or discharge outside the manufacturer's specifications.
  • Dispose of lithium-ion batteries in household trash.

Recycle batteries only through approved recycling facilities.


If a Battery Fails

Immediately stop using any battery that becomes unusually hot, swells, leaks, hisses, or emits smoke.

If it can be done safely:

  • Move the battery to a non-flammable surface such as concrete or sand.
  • Keep it away from combustible materials.
  • Allow the battery to cool from a safe distance.

For lithium-ion battery fires, an ABC dry chemical extinguisher may be used. Large amounts of water may also be effective for cooling lithium-ion cells and helping prevent fire spread. Continue monitoring the battery after the incident, as damaged cells may reignite.

If the fire cannot be safely controlled, evacuate the area immediately and contact emergency services.

CH-AmpX Product Disclaimer

CH-AmpX supplies lithium-ion batteries and battery components intended for knowledgeable users and professional battery pack builders.

Customers are responsible for ensuring that all batteries are used, charged, stored, transported, and installed according to manufacturer specifications, industry best practices, and applicable regulations.

CH-AmpX shall not be held liable for any injury, property damage, equipment failure, financial loss, or other damages resulting from:

  • Improper handling or misuse
  • Incorrect charging practices
  • Unauthorized modification
  • Improper storage or transportation
  • Failure to follow recommended safety procedures
  • Use outside manufacturer specifications

By purchasing from CH-AmpX, you acknowledge the inherent risks associated with lithium-ion batteries and accept full responsibility for their safe handling and use.

View Complete Safety Guide
Weight 0.1808 lbs
Dimensions 2.835 × 0.866 × 0.866 in