LINKDATA INR21700S-50T 21700 Lithium-Ion Cell
The LINKDATA INR21700S-50T is a rechargeable 21700 lithium-ion cell with 5,000 mAh typical capacity, 4,900 mAh rated capacity, and 3.6 V nominal voltage. Linkdata specifies a maximum continuous discharge of 60 A outside cycling duty and a 125 A pulse for 10 seconds at 50% state of charge and 25 ± 2°C.
Technical Specifications
| Specification | Value |
|---|---|
| Model | INR21700S-50T |
| Manufacturer | Linkdata New Energy Co., Ltd. |
| Format | 21700 cylindrical |
| Chemistry | Rechargeable lithium-ion |
| Typical capacity | 5,000 mAh |
| Rated capacity | 4,900 mAh |
| Nominal voltage | 3.6 V |
| Rated energy (sleeve marking) | 18.0 Wh (§4.3) |
| Standard-discharge energy | ≥17.6 Wh at 25 ± 2°C under the standard discharge test (§3.3). |
| Maximum continuous discharge current | 60 A maximum outside cycling duty (Rev. A0, §3.11). |
| Maximum continuous charge current | 8 A (§3.10) |
| Full-charge peak discharge test | 40C (200 A at 5 Ah) for 10 s at 100% state of charge and 25 ± 2°C, with a minimum terminal voltage of 2.50 V (§6.1.11). |
| Cell weight | 68.5 ± 1.5 g |
| Cell dimensions (with sleeve) | Ø21.35 ± 0.15 mm × 70.7 ± 0.2 mm |
Safety Warning
Use this cell with appropriate protection circuitry and a compatible lithium-ion charger. Follow Linkdata’s current, voltage, and temperature guidance and protect the terminals from short circuits.
Cell Specification
| Specification | Value |
|---|---|
| Cell model | INR21700S-50T |
| Standard discharge capacity | 5,000 mAh typical and 4,900 mAh rated under standard charge and discharge (§3.1). |
| Rated discharge capacity (10C) | ≥96% of standard discharge capacity in the 10C test to 2.50 V (§6.1.1). |
| Nominal voltage | 3.6 V |
| Standard charge | 5.0 A (1C) CC/CV to 4.20 V, terminating at 100 mA at 25 ± 2°C (§5.2). |
| Rated charge | N/A |
| Charging time | ≤2 hours under standard charge, for reference (§3.7). |
| Standard discharge | 1.0 A (0.2C) to 2.50 V at 25 ± 2°C (§5.3). |
| Max. continuous discharge current | 60 A maximum outside cycling duty (Rev. A0, §3.11). |
| Max. pulse discharge current | 125 A for 10 s at 50% state of charge and 25 ± 2°C (§3.9). |
| Charge cut-off voltage | 4.20 V (§3.4) |
| Discharge cut-off voltage | 2.50 V standard (§3.5) |
| Cycle life (high-rate, 30A) | N/A |
| Cycle life (high-rate, 40A) | ≥600 cycles at 25 ± 2°C with 8 A charge and 40 A discharge to 2.50 V or a 75°C cutoff. The test ends after two consecutive cycles below 60% of initial capacity (§6.1.8). |
| Retention characteristics | 30-day capacity recovery criteria of ≥97% at 25°C and ≥92% at 60°C (§§6.1.5–6.1.6). |
| Initial impedance | ≤4 mΩ AC at 1 kHz and 30% state of charge (§3.13). |
| Operating cell surface temperature | §3.15 lists −20°C to +60°C for charging and −40°C to +80°C for discharging. §10.1 design guidance lists 0°C to +60°C for charging and −30°C to +80°C for discharging. |
| Storage conditions | At 20–30% state of charge, −20°C to +60°C for 1 month, −20°C to +45°C for 3 months, or −20°C to +23°C for 1 year (§3.14). |
| Shipment voltage | N/A |
| Cell weight | 68.5 ± 1.5 g |
| Cell dimensions (with sleeve) | Ø21.35 ± 0.15 mm × 70.7 ± 0.2 mm |





Reviews